Sinexcel DC charger
SEC 240
Up to 240 kW across two connectors, boosting to 500 A. Around twenty minutes from empty to 80% on a 350 A cable.
Public fast charging
with a queue behind it.
The SEC 240 splits its output between two connectors as the cars ask for it, so a single vehicle can take the full rating and two vehicles share it. Sinexcel lists it in six ratings from 120 kW up, and the cabinet takes OTA firmware updates.
About 20 minutes to 80%
Sinexcel's own figure for a car on the 350 A cable. That is the number that decides how many vehicles a bay serves in a day.
Six ratings, one cabinet
120, 140, 160, 180, 200 or 240 kW. Size it against the grid connection rather than buying capacity the site cannot feed.
Options for awkward sites
Tilt protection, flood protection, fire protection and a heater are all available, which matters more in a Nordic forecourt than in the brochure photo.
Dual-connector cabinet with cable management.
Specification
120–240 kW
Rated DC output
500 A
Boost output current
2 × CCS2
200–1000 V, 5 m cables
≤540 kg
850 × 750 mm footprint
Grid input
Charging output
Cabinet
Environment
Communication and payment
Compliance
Standards and compliance
Built to the European charging standards, with ISO 15118 on the vehicle side and OCPP to the back office you choose.